Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Antibody

Catalog # Availability Size / Price Qty
FAB7089G-100ug
Detection of S1P1/EDG-1 in Mouse Thymocytes by Flow Cytometry.
2 Images
Product Details
FAQs
Supplemental Products
Reviews (1)

Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Antibody Summary

Species Reactivity
Mouse
Specificity
Detects mouse S1P1/EDG‑1 peptide in direct ELISAs.
Source
Monoclonal Rat IgG2A Clone # 713412
Purification
Protein A or G purified from hybridoma culture supernatant
Immunogen
Mouse S1P1/EDG‑1 synthetic peptide (T4-H28)
Accession # O08530
Formulation
Supplied in a saline solution containing BSA and Sodium Azide.
Label
Alexa Fluor 488 (Excitation= 488 nm, Emission= 515-545 nm)

Applications

Recommended Concentration
Sample
Flow Cytometry
0.25-1 µg/106 cells
Mouse thymocytes; transfectants

Please Note: Optimal dilutions should be determined by each laboratory for each application. General Protocols are available in the Technical Information section on our website.

Scientific Data

Flow Cytometry Detection of S1P1/EDG-1 antibody in Mouse Thymocytes antibody by Flow Cytometry. View Larger

Detection of S1P1/EDG-1 in Mouse Thymocytes by Flow Cytometry. Mouse thymocytes were stained with Rat Anti-Mouse CD4 APC-conjugated Monoclonal Antibody (Catalog # FAB554A) and either (A) Rat Anti-Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Monoclonal Antibody (Catalog # FAB7089G) or (B) Rat IgG2A Alexa Fluor 488 Isotype Control (IC006G). View our protocol for Staining Membrane-associated Proteins.

Flow Cytometry View Larger

Detection of S1P1/EDG‑1 in mEDG-1 HEK transfectants by Flow Cytometry Rat Anti-Mouse S1P1/EDG‑1 Alexa Fluor® 488‑conjugated Monoclonal Antibody (Catalog # FAB7089G) detection in mEDG-1 HEK/mCherry transfectants (A) or irrelevant mCherry transfectants (B). View our protocol for Staining Membrane-associated Proteins.

Reconstitution Calculator

Reconstitution Calculator

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial. Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

=
÷

Preparation and Storage

Reconstitution
Reconstitution default not known
Loading...
Shipping
The product is shipped with polar packs. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage
Protect from light. Do not freeze.
  • 12 months from date of receipt, 2 to 8 °C as supplied.

Background: S1P1/EDG-1

S1P1 (sphingosine 1-phosphate receptor-1), also known as EDG-1 (endothelial differentiation, G-protein coupled receptor-1) or S1PR1 (sphingosine-1-phosphate receptor 1) is a widely expressed, 37-40 kDa, G protein coupled receptor within the S1P subfamily of the EDG family. S1P1 is one of five receptors for the bioactive lipid S1P and mediates most of S1P effects on angiogenesis, vascular maturation, and cell migration, especially T cell egress from lymphoid organs. Human and mouse S1P1 share 84% amino acid identity within the N-terminal extracellular portion used as an immunogen.

Long Name
Endothelial Differentiation Gene 1
Entrez Gene IDs
1901 (Human); 13609 (Mouse)
Alternate Names
CD363 antigen; CD363; CHEDG1; D1S3362; EDG1; EDG-1; EDG1edg-1; Endothelial differentiation G-protein coupled receptor 1; endothelial differentiation, sphingolipid G-protein-coupled receptor, 1; FLJ58121; S1P receptor 1; S1P receptor Edg-1; S1P1; S1P1ECGF1; S1PR1; sphingosine 1-phosphate receptor 1; sphingosine 1-phosphate receptor EDG1; Sphingosine 1-phosphate receptor Edg-1; sphingosine-1-phosphate receptor 1

Product Datasheets

You must select a language.

x

Product Specific Notices


This product is provided under an agreement between Life Technologies Corporation and R&D Systems, Inc, and the manufacture, use, sale or import of this product is subject to one or more US patents and corresponding non-US equivalents, owned by Life Technologies Corporation and its affiliates. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product only in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The sale of this product is expressly conditioned on the buyer not using the product or its components (1) in manufacturing; (2) to provide a service, information, or data to an unaffiliated third party for payment; (3) for therapeutic, diagnostic or prophylactic purposes; (4) to resell, sell, or otherwise transfer this product or its components to any third party, or for any other commercial purpose. Life Technologies Corporation will not assert a claim against the buyer of the infringement of the above patents based on the manufacture, use or sale of a commercial product developed in research by the buyer in which this product or its components was employed, provided that neither this product nor any of its components was used in the manufacture of such product. For information on purchasing a license to this product for purposes other than research, contact Life Technologies Corporation, Cell Analysis Business Unit, Business Development, 29851 Willow Creek Road, Eugene, OR 97402, Tel: (541) 465-8300. Fax: (541) 335-0354.

FAQs

  1. Can staining with Mouse S1P1/EDG-1 conjugated Antibody, catalog # FAB7089*,  be carried out at 4°C? 

    • There is evidence that G protein family proteins require staining at room temperature (RT) or even 37 °C, so this is what we would recommend.  Staining for 45 minutes is optimal with this antibody. 

View all Antibody FAQs
Loading...

Reviews for Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Antibody

Average Rating: 3 (Based on 1 Review)

5 Star
0%
4 Star
0%
3 Star
100%
2 Star
0%
1 Star
0%

Have you used Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Antibody?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review

Filter by:


Mouse S1P1/EDG-1 Alexa Fluor® 488-conjugated Antibody
By Colleen Netherby on 07/20/2018
Application: Flow Sample Tested: Peripheral blood leukocytes Species: Mouse

When used at a 1:10 dilution this antibody can reliably be used to detected expression of S1P1 on peripheral blood lymphocytes. When I tired to used this antibody at a lower concentration (higher dilution) I was not able to detect staining. Thus, a large amount of antibody is needed to stain each sample.