Human Magnetic Luminex® Performance Assay MMP Base Kit
Build your own Luminex Assay with our Luminex Assay Customization Tool.
U.S. orders usually ship in 2-3 business days
Build NowHuman Magnetic Luminex® Performance Assay MMP Base Kit Summary
Panel | Luminex Performance Human MMP Panel |
Assay Type | Magnetic bead-based multiplex assay for the Luminex® platform |
Format | 1 x 96-well microplate and Magnetic antibody-coated beads |
Species | Human |
Analytes Detected | Please see analyte list in assay customization tool below. |
Performance Validation | Our Luminex High Performance Assays undergo our most extensive validation testing. All Luminex High Performance Assay Panels are validated for use with serum and plasma samples. Some High Performance Assays are additionally validated for cell culture supernatants, milk, saliva, or urine, as indicated on the individual product data sheets. Luminex High Performance Assays are tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types. Recovery values for individual samples in validated sample types are also tested. Validation data for each analyte can be found in the product datasheet. |
Make your selections below to configure your assay
Not finding your analyte of interest? View our complete Luminex offering in the full version of our Luminex Assay Customization Tool. We also offer Custom Luminex Services.
Magnetic Luminex High Performance Assays are flexible bead-based multiplex assays. They allow up to 50 user-defined target analytes to be simultaneously profiled using cell culture supernates, serum, or plasma samples. Some panels are also validated with human milk, saliva, and/or urine samples.
- Simultaneously profile up to analytes of your choice in one sample
- Magnetic format allows for easier wash steps
- Undergoes similar validation testing as Quantikine® ELISA Kits
- Precise and Specific
- Requires a small sample volume (<50 µL)
- Run your assay in just 3-5 hours
- Mass-calibrated standards for consistent results with every new lot of material
- Enough reagents for one 96-well plate
- Standard Cocktail(s)
- Bead Diluent
- Biotin Antibody Diluent
- Calibrator Diluent
- Wash Buffer
- Streptavidin-PE
- One flat-bottom 96-well Microplate
- Foil Plate Sealers (4)
- Mixing Bottle
- Standard Value Card**
**A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Base Kit.
- User-mix antibody-coated Magnetic beads in individual vials
- User-mixed cocktail of biotinylated detection antibody
Precision
Intra-Assay Precision - is generated from the mean of the %CV's from 60 reportable results across three different concentrations of analytes in a single serum assay. Inter-Assay Precision - is generated from the mean of the %CV's across three different concentrations of analytes across 72 different serum assays. |
||
n=60 (20x3 levels) | n=72 | |
---|---|---|
Analyte | Intra-Assay (%CV) | Inter-Assay (%CV) |
EMMPRIN/CD147 | 6.5 | 9.8 |
MMP-1 | 8.7 | 15.8 |
MMP-2 | 7.9 | 11.6 |
MMP-3 | 6 | 10.3 |
MMP-7 | 7 | 9.8 |
MMP-8 | 6.1 | 11.2 |
MMP-9 | 5 | 10.5 |
MMP-10 | 6.1 | 10.8 |
MMP-12 | 7.9 | 10.8 |
MMP-13 | 5 | 11.8 |
Accuracy
Linearity - The data represents mean spiked or natural linearity in serum matrix samples. Spike Recovery - The data represents mean percent recovery of spiked standards ranging from low, medium, and high concentration in serum matrix samples. |
||
Linearity | Spiked Recovery |
|
---|---|---|
Analyte | Average % | Average % |
EMMPRIN/CD147 | 81 | 105 |
MMP-1 | 109 | NO |
MMP-2 | 103 | 106 |
MMP-3 | 99 | NO |
MMP-7 | 96 | 104 |
MMP-8 | 110 | 85 |
MMP-9 | 115 | NO |
MMP-10 | 100 | 105 |
MMP-12 | 109 | 87 |
MMP-13 | 107 | 111 |
Assays for the Luminex platform are offered as High Performance Assays or Assays. The Luminex High Performance Assays are fully validated panels with a focused selection of analytes. They are available in We Mix, You Mix, and Predetermined formats. The Luminex Assays allows for the maximum number of analytes in a multiplex and is supplied as a premixed kit. View a table comparing the features and benefits of these bead-based multiplex assays.
Magnetic Luminex High Performance Assays are designed for use with the Luminex MAGPIX CCD Imager. Alternatively, kits can be used with the Luminex 100/200™ or FLEXMAP 3D, dual laser, flow-based sorting and detection platforms.
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. One laser is bead-specific and determines which analyte is being detected. A magnet in the analyzer captures and holds the superparaMagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.
Product Datasheets
Citations for Human Magnetic Luminex® Performance Assay MMP Base Kit
R&D Systems personnel manually curate a database that contains references using R&D Systems products. The data collected includes not only links to publications in PubMed, but also provides information about sample types, species, and experimental conditions.
12
Citations: Showing 1 - 10
Filter your results:
Filter by:
-
Human apical-out nasal organoids reveal an essential role of matrix metalloproteinases in airway epithelial differentiation
Authors: Li, L;Jiao, L;Feng, D;Yuan, Y;Yang, X;Li, J;Jiang, D;Chen, H;Meng, Q;Chen, R;Fang, B;Zou, X;Luo, Z;Ye, X;Hong, Y;Liu, C;Li, C;
Nature communications
Species: Human
Sample Types: Organoid Culture
-
Increased Matrix Metalloproteinase-2 and Matrix Metalloproteinase-3 Concentrations in Corneal Epithelium of Patients with Recurrent Corneal Erosions
Authors: K Jadczyk-So, W Garczorz, B Buba?a-Sta, T Francuz, E Mrukwa-Kom
Journal of Ophthalmology, 2022-09-25;2022(0):5024037.
Species: Human
Sample Types: Cell Lysates
-
Effect of BCG vaccination on proinflammatory responses in elderly individuals
Authors: N Pavan Kuma, C Padmapriya, A Rajamanick, SB Marinaik, A Nancy, S Padmanaban, N Akbar, M Murhekar, S Babu
Science Advances, 2021-08-04;7(32):.
Species: Human
Sample Types: Plasma
-
Evaluation of serum MMP-2 and MMP-3, synovial fluid IL-8, MCP-1, and KC concentrations as biomarkers of stifle osteoarthritis associated with naturally occurring cranial cruciate ligament rupture in dogs
Authors: S Malek, HY Weng, SA Martinson, MC Rochat, R Béraud, CB Riley
PLoS ONE, 2020-11-19;15(11):e0242614.
Species: Canine
Sample Types: Serum
-
Characterization of the local wound environment following treatment of chronic leg ulcers with SIS wound matrix
Authors: JP Hodde, MC Hiles, DW Metzger
J Tissue Viability, 2019-12-13;0(0):.
Species: Human
Sample Types: Wound Fluid
-
Plasma levels of C-reactive protein, matrix metalloproteinase-7 and lipopolysaccharide-binding protein distinguish active pulmonary or extrapulmonary tuberculosis from uninfected controls in children
Authors: VVS Albuquerqu, NP Kumar, KF Fukutani, B Vasconcelo, MB Arriaga, PS Silveira-M, S Babu, BB Andrade
Cytokine, 2019-07-09;123(0):154773.
Species: Human
Sample Types: Plasma
-
Effects of aqueous suppressants and prostaglandin analogues on early wound healing after glaucoma implant surgery
Authors: KI Jung, JE Woo, CK Park
Sci Rep, 2019-03-27;9(1):5251.
Species: Rabbit
Sample Types: Aqueous Humor
-
Marked infiltration of neutrophils at the upper palpebral conjunctiva in patients with chronic graft-versus-host disease
Authors: YS Byun, YS Yoo, MJ Kang, WJ Whang, KS Na, JW Mok, CK Joo
Ocul Surf, 2018-12-20;0(0):.
-
Glucocorticoid sensitivity and inflammatory status of peripheral blood mononuclear cells in patients with coronary artery disease
Authors: S Jönsson, AK Lundberg, RWS Chung, L Jonasson
Ann. Med., 2018-02-28;0(0):1-24.
Species: Human
Sample Types: Plasma
-
The impact of human adipose tissue-derived stem cells on breast cancer cells: implications for cell-assisted lipotransfers in breast reconstruction
Authors: E Koellenspe, LC Bonnert, I Zoernig, F Marmé, S Sandmann, G Germann, F Gramley, U Leimer
Stem Cell Res Ther, 2017-05-25;8(1):121.
Species: Human
Sample Types: Cell Culture Supernates
-
Tumor Necrosis Factor-alpha, Matrix-Metalloproteinases 8 and 9 Levels in the Saliva Are Associated with Increased Hemoglobin A1c in Type 1 Diabetes Subjects.
Authors: Kuehl M, Rodriguez H, Burkhardt B, Alman A
PLoS ONE, 2015-04-27;10(4):e0125320.
Species: Human
Sample Types: Saliva
-
Overexpression of MMP-9 and its inhibitors in blood mononuclear cells after myocardial infarction--is it associated with depressive symptomatology?
Authors: Jonsson S, Lundberg A, Jonasson L
PLoS ONE, 2014-08-25;9(8):e105572.
Species: Human
Sample Types: Cell Culture Supernates
FAQs
No product specific FAQs exist for this product, however you may
View all Luminex Assay FAQsReviews for Human Magnetic Luminex® Performance Assay MMP Base Kit
Average Rating: 4.5 (Based on 2 Reviews)
Have you used Human Magnetic Luminex® Performance Assay MMP Base Kit?
Submit a review and receive an Amazon gift card.
$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image
$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image
Filter by: