Human Tumor Biomarker Luminex® Performance Assay Summary

Panel Luminex Performance Human Tumor Biomarker Panel
Assay Type Magnetic bead-based multiplex assay for the Luminex® platform
Format 1 x 96-well microplate and Magnetic antibody-coated beads
Species Human
Analytes Detected Please see analyte list in assay customization tool below.
Performance Validation Our Luminex High Performance Assays undergo our most extensive validation testing. All Luminex High Performance Assay Panels are validated for use with serum and plasma samples. Some High Performance Assays are additionally validated for cell culture supernatants, milk, saliva, or urine, as indicated on the individual product data sheets. Luminex High Performance Assays are tested for sensitivity (three-quarters the low standard), intra-assay precision, inter-assay precision, and to ensure assay linearity for validated sample types. Recovery values for individual samples in validated sample types are also tested. Validation data for each analyte can be found in the product datasheet.

Make your selections below to configure your assay

Filter Analytes
Select All Select None

Assays

Below are kits that are available based on your selections. These selections may be further customized before adding to the cart or emailing the configuration to your purchasing department or local distributor to place your order. Selected analytes may be included in more than one High Performance Assay. All assay options are displayed.

If you run into bead region incompatibilities, send your Luminex code to our team and find out more.

How would you like these analytes mixed?

Premixed
User Mixed
Please select at least one mixing option to see the kits.

Would you like to split based on dilution?

Do not split
Split based on serum
Split based on plasma
Split based on cell culture supernates

Not finding your analyte of interest? View our complete Luminex offering in the full version of our Luminex Assay Customization Tool. We also offer Custom Luminex Services.

Product Features

Magnetic Luminex High Performance Assays are flexible bead-based multiplex assays. They allow up to 50 user-defined target analytes to be simultaneously profiled using cell culture supernates, serum, or plasma samples. Some panels are also validated with human milk, saliva, and/or urine samples.

  • Simultaneously profile up to analytes of your choice in one sample
  • Magnetic format allows for easier wash steps
  • Undergoes similar validation testing as Quantikine® ELISA Kits
  • Precise and Specific
  • Requires a small sample volume (<50 µL)
  • Run your assay in just 3-5 hours
  • Mass-calibrated standards for consistent results with every new lot of material
  • Enough reagents for one 96-well plate
Kit Components
  • Premixed cocktail of antibody-coated Magnetic beads
  • Premixed cocktail of biotinylated detection antibody
  • Standard Cocktail(s)
  • Bead Diluent
  • Biotin Antibody Diluent
  • Calibrator Diluent
  • Wash Buffer
  • Streptavidin-PE
  • One flat-bottom 96-well Microplate
  • Foil Plate Sealers (4)
  • Mixing Bottle
  • Standard Value Card**

**A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Kit.

Precision

Intra-Assay Precision - is generated from the mean of the %CV’s from 40 reportable results across two different concentrations of analytes in a single serum assay.

Inter-Assay Precision - is generated from the mean of the %CV’s across two different concentrations of analytes across thirty six different serum assays.

  n=40 (20x2 levels) n=36
Analyte Intra-Assay (%CV) Inter-Assay (%CV)
AFP 7.0 10.3
CA125/MUC16 6.8 9.9
CA15-5/MUC-1 6.3 8.4
CA19-9 4.0 10.7
CD40 Ligand/TNFSF5 4.8 8.8
CEACAM-5/CD66e 8.0 9.7
Chromogranin A 3.5 9.0
CYFRA21-1 5.7 9.7
Enolase 2 8.6 10.8
Fas/TNFRSF6/CD95 5.6 8.6
Fas Ligand 6.2 9.4
FGF basic 2.4 8.1
Glypican-1 7.9 9.7
HCG-beta 4.8 7.9
HE4/WFDC2 5.2 8.6
HGF 6.2 9.0
IL-6 3.7 8.0
IL-8/CXCL8 5.9 9.3
Leptin/OB 4.4 8.8
MIF 5.1 8.0
Osteopontin/OPN 5.9 9.2
Kallikrein 3/PSA 5.1 8.7
Prolactin 7.9 9.7
SCF/c-kit Ligand 6.1 9.7
TGF alpha 5.4 9.1
Thyroglobulin 9.0 10.0
TNF alpha 4.0 9.5
VEGF 4.9 8.7

Accuracy

Linearity - The data represents mean spiked or natural linearity in serum matrix samples (n=4).

Spike Recovery - The data represents mean percent recovery of spiked standards ranging from low, medium, and high concentration in serum matrix samples (n=4).

  Linearity Spiked
Recovery
Analyte Average % Average %
AFP* 117 HE
CA125/MUC16 120 86.8
CA15-3/MUC-1* 113 HE
CA19-9 132 63.9
CD40 Ligand/TNFSF5* 107 HE
CEACAM-5/CD66e* 123 HE
Chromogranin A* 111 HE
CYFRA21-1 129 78.2
Enolase 2 127 62.5
Fas/TNFRSF6/CD95* 106 HE
Fas Ligand 122 82.4
FGF basic 135 74.6
Glypican-1 126 72.9
HCG-B 131 58.1
HE4/WFDC2* 114 HE
HGF 134 62.5
IL-6 128 65.6
IL-8/CXCL8* 111 HE
Leptin/OB* 110 HE
MIF* 134 HE
Osteopontin/OPN* 105 HE
Kallikrein-3/PSA 122 78.9
Prolactin* 106 HE
SCF/c-kit Ligand 185 42.8
TGF alpha 122 77.6
Thyroglobulin 123 65.8
TNF alpha 170 54.2
VEGF 123 67.5
*Natural linearity
HE -
 Spiked recovery was not observed due to natural linearity in high endogenous samples
Which Luminex Assay is right for me?

Assays for the Luminex platform are offered as High Performance Assays or Assays. The Luminex High Performance Assays are fully validated panels with a focused selection of analytes. They are available in We Mix, You Mix, and Predetermined formats. The Luminex Assays allows for the maximum number of analytes in a multiplex and is supplied as a premixed kit. View a table comparing the features and benefits of these bead-based multiplex assays.

More Information About Magnetic Bead-based Multiplex Kits For The Luminex® Platform

Magnetic Luminex High Performance Assays are designed for use with the Luminex MAGPIX CCD Imager. Alternatively, kits can be used with the Luminex 100/200™ or FLEXMAP 3D, dual laser, flow-based sorting and detection platforms.

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. One laser is bead-specific and determines which analyte is being detected. A magnet in the analyzer captures and holds the superparaMagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.

Scientific Data

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Standard Curves View Larger

Human Tumor Biomarker Luminex Panel Standard Curves

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Serum Sample Values View Larger

Human Tumor Biomarker Luminex Panel Serum Sample Values Serum samples from 20 apparently healthy individuals were run on the Human Tumor Biomarker Luminex Panel and sample values plotted. Minimum and maximum values shown by exterior lines, the box represents the 1st and 3rd quartiles with the center line representing the median.

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay EDTA Plasma Sample Values View Larger

Human Tumor Biomarker Luminex Panel EDTA Plasma Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Heparin Plasma Sample Values View Larger

Human Tumor Biomarker Luminex Panel Heparin Plasma Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Cell Culture Supernate Sample Values View Larger

Human Tumor Biomarker Luminex Panel Cell Culture Supernate Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Cell Lysate Sample Values View Larger

Human Tumor Biomarker Luminex Panel Cell Lysate Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Tissue Lysate Sample Values View Larger

Human Tumor Biomarker Luminex Panel Tissue Lysate Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Healthy Controls vs. Colorectal Serum Samples View Larger

Human Tumor Biomarker Luminex Panel Healthy Controls vs. Colorectal Cancer Serum Samples Colorectal cancer serum samples were tested alongside healthy controls on the Human Tumor Biomarker Panel and significant differences were observed over many analytes. A selection of these are shown below.

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Healthy Controls vs. Pancreatic Cancer Serum Samples View Larger

Human Tumor Biomarker Luminex Panel Healthy Controls vs. Pancreatic Cancer Serum Samples Pancreatic cancer serum samples were tested alongside healthy controls on the Human Tumor Biomarker Panel and significant differences were observed over many analytes. A selection of these are shown below.

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Protein-Plus Streck Plasma Sample Values View Larger

Human Tumor Biomarker Luminex Panel Protein-Plus Streck Plasma Sample Values

Multiplex Immunoassay Human Tumor Biomarker Cancer Assay Streck Plasma Sample Values View Larger

Human Tumor Biomarker Luminex Panel Streck Plasma Sample Values

Product Datasheets

You must select a language.

x
Product Specific Notices
Luminex® is a registered trademark of Luminex Corporation.

FAQs

No product specific FAQs exist for this product, however you may

View all Luminex Assay FAQs

Reviews for Human Tumor Biomarker Luminex® Performance Assay

Average Rating: 5 (Based on 1 Review)

5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%

Have you used Human Tumor Biomarker Luminex® Performance Assay?

Submit a review and receive an Amazon gift card.

$25/€18/£15/$25CAN/¥75 Yuan/¥2500 Yen for a review with an image

$10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen for a review without an image

Submit a Review

Filter by:


Human Tumor Biomarker Luminex® Performance Assay
By Anonymous on 10/11/2024
Sample Tested: EDTA Plasma